tamsy --- 15 years ago -

I would like recommendations for a good a/c repair company that wont rip me off and can do a good job. 

ghostpost --- 15 years ago -

do a search on here to read the many recommendations for Kingwood Air Solutions. 

ghostpost --- 15 years ago -

worth repeating, lol 

debrah --- 15 years ago -

This guy is awesome!

Action Air & Heat - Leroy
281-931-3034

He went above and beyond for me and my family. I could never think him enough for helping me!!! 

crazypinetrees --- 15 years ago -

Luv Kingwood Air Solutions! 

NICKLE PICKLE --- 15 years ago -

Call Jeff Jackson 713-398-7523. He's my brother, he does good work and is HONEST. He works on most of my friends a/c's. 

LavaSurfer --- 15 years ago -

We had our entire system replaced using Guy's heating and air. http://www.guysac.com/

They were absolutely fabulous from start to finish and ever since as well. Unfortunately, since it is "peak" season, any repair or replacement will cost you tons more than it would in the winter to do the exact same job. Supply and demand. Sorry you are having trouble right now :-( 

mamadog53 --- 15 years ago -

We also used Guy's last week when outside fan unit froze up. They were able to come out and diagnose the problem, get the part ordered and the unit repaired within 24 hours. 

newstufftosay --- 15 years ago -

Call Jeff Jackson 713-398-7523. He's my brother,
Nickle Pickle - I think I might know your brother - does his middle name start with J? 

cat person --- 15 years ago -

Call Adam at Direct Comfort he's honest and a really nice guy 713-557-9874 

kwoodmom2 --- 15 years ago -

Dan Rodgers from Danair 7134750646
weve used him several times and he is very good and pretty reasonably priced. he came out one time and it took him 10 mins to fix the problem and he didnt charge us except the service call fee. 

newstufftosay --- 15 years ago -

Tamsy - what is wrong with your a/c. I know a lot of ac mechanics, I could ask them possible solutions. Sometimes it a simple fix (not always). 

doglady --- 15 years ago -

I don't know the name of his company, just his name - Brian Fuhre - I know the people at Pampered Paws have used him and think he is awesome. Maybe you could call them and they could give you his number. ppaws-281-359-7297 

quiettype --- 15 years ago -

doglady that is Kingwood Air Solutions I believe. Last time I saw a number for them posted it was 281-358-2422. 

doglady --- 15 years ago -

thanks qt - haven't been on here in ages - hope you are well:) 

thelees --- 15 years ago -

Kingwood Air Solutions is who we use. Brian is honest and stands by his work. 

love4bdd --- 15 years ago -

Bryan will be out here today to replace our motor. We've been without central AC since Saturday afternoon! Only the 3 HOTTEST days EVER! No better time! Pffft.
But Bryan is really good and VERY honest! Kingwood Air Solutions ~ Office: 281-358-2422
Cell: 281-935-4678 

kwoodmom2 --- 15 years ago -

our ac keeps freezing up outside..we just turn it off for a couple hours to melt the ice then back on and helps a little, any other suggestions? 

tinman --- 15 years ago -

You are probably low on freon.

Either you have a leak outside around the condenser, or you have a leak in your evaporator coil. If you feel around with your hands and you run across a patch of oily water or condensate, then your problem is right around there some where.

When you turn on the outdoor unit, do both the fan and compressor come on? If so then low freon is the answer.

When you call for a/c inside, does the air come out of the grills, even though it might be warm? If so, then you are probably low on freon.

If you have a large enough leak that you need to add freon, then you probably have air in the system too. Have your guy pump the unit down.

He'll have to do that to fix the leak. That means he sucks all of the freon into the compressor and then valves off the compressor so no gas escapes. Then have him pull a vacuum on the entire line set to make sure the leak has been fixed. Don't let him fix the leak and then put freon in without pulling a good vacuum.

The vacuum does two things. It evacuates your system of air. Air inside your copper is not good. The vacuum also allows him to check and make sure he has no more leaks without putting in more freon.

Good Luck!! 

kwoodmom2 --- 15 years ago -

tinman, yes the fan and compressor do come on when the unit is on but doesnt seem to be any air blowing out of the vents. we checked in the attic to see if we were losing air from the ducts but didnt seem to be 

tinman --- 15 years ago -

Ok...could be a couple of things.

More than likely you have a sheet of ice built up on the face of your evaporator coil and that will not let any air pass through. If the air can't get across the coil face, it can't get to your grills. It usually takes several hours to sometimes all day to get the ice melted all the way.

If your attic unit is blowing but nothing is coming out of the grills, then ice on the coil is the culprit.

Have you changed your air filters recently? Clogged up filters will also cause every symptom you are describing.

It's also possible that the fan inside of your attic furnace isn't working properly. Poor air flow across the coil is the culprit, but the cause of the poor air flow is up in the air still. 

kwoodmom2 --- 15 years ago -

tinman,ill try changing the air filters. should i shut off the ac unit to let the ice melt? then what do i do after? 

tinman --- 15 years ago -

Well...once the ice is melted, turn it back on. The chances are pretty good that the evaporator coil will just freeze up again.

The quick, cheap and easy fix is if your filters are clogged and no return air is crossing the coil face.

After that, the causes of your problem and the solutions become more complicated and expensive.

If your guy says you have a leak in your evap coil, ask him to show you exactly where it is, and then feel around the area for the oily residue I spoke of earlier. It should be there.

Good Luck 

kwoodmom2 --- 15 years ago -