Froggie --- 13 years ago -

The breaker for the heater blower keeps tripping. It started a few weeks ago when I was constantly switching from a/c to heat.

I got up this morning and it was really cold in the house. I checked the breaker and it was tripped again. I switched it back to ON but it only lasts a few seconds before it trips again.

Who should I call? An electrician or a heating company.

Thanks all! 

FabFive --- 13 years ago -

Electrician. Heat pulls a bunch of amps. In the mean time, don't run your dryer or vacuum while the heat is on. 

Froggie --- 13 years ago -

Nothing is running except the TV and a lamp. I've turned on the gas fireplace because I can't keep the heat going and it's getting pretty darn chilly in the house.

It's a 10 amp breaker, I'm wondering if it just needs to be replaced, and how difficult that is. DH is out of town....of course. Ugh 

tinman --- 13 years ago -

Is your heat gas or electric.

If it is electric, then you have a heater coil trying to go to ground.

If it is gas, then you have an electrical problem.

Also, there is an outside chance your thermostat is bad. Is your tstat digital or analog? 

FabFive --- 13 years ago -

I don't think it's difficult but it's not cheap. Call out someone trustworthy. Do you want to come over to keep warm?? 

FabFive --- 13 years ago -

Now that is someone who knows what they are talking about! 

Froggie --- 13 years ago -

Our heat is gas. I'm not sure what kind of tstat we have, it's digital...I think, I'm not sure what an analog tstat is.

Fab, thanks but I've turned on the fireplace so we will be ok, I'm going to go take my shower now before it gets to cold in that part of the house. 

FabFive --- 13 years ago -

Analog is the opposite of digital. Like a regular watch compared to digital. 

Froggie --- 13 years ago -

Oh, then it's an analog. 

kwgraniteguy --- 13 years ago -

My initial thought is an aged breaker. If it has been intermitant and now consistant sugests to me the breaaker can no longer carry the surge/load at start up. 

tinman --- 13 years ago -

You most definitely can have a breaker issue, but not likely.

The only thing pulling amperage during gas heat mode is the fan motor itself. It is a 1/4 hp, 1075 rpm motor rated at 1 or two amps while running and probably 8-10 amps while locked.

Breakers trip due to a build up of heat. Heat in electrical circuits is caused by resistance. So, you either have a weak breaker or you have some resistance somewhere in your line voltage.

Either way, an a/c company is who you need to call. 

Gigix4 --- 13 years ago -

I don't think a breaker is hard to replace. Is it?
If you are not comfortable with trying to change the breaker, then call an electrician asap.
It's not going to get any warmer today and froggies should not get cold. 

tinman --- 13 years ago -

You should under no circumstances change your breaker unless you are a professional.

Electricity is some nasty stuff and you could be putting your house, and your life, in danger by doing something you have no experience with. 

Gigix4 --- 13 years ago -

Thanks tinman. You are so right - electricity can kill pretty fast. 

redraider --- 13 years ago -

I am a contractor and it sounds like you have an old breaker that needs
to be replaced. it is not that hard to diy but i would suggest letting a pro handle it if not comfortable with electricity. 

Froggie --- 13 years ago -

Ok, thanks for the advice, now...next question

Who do you recommend I call? Any recommendations on a trustworthy company? 

FabFive --- 13 years ago -

Make sure you call someone that guarantees their work. Not sure who that is but I think reputable is key. 

MonzaRacer --- 13 years ago -

It's a 10 amp breaker,

If you have the manual for your furnace, check to see if that is the right amperage breaker, most I have seen on furnaces have been 15. I just checked mine and it's a 20. 

Froggie --- 13 years ago -

I don't have the manual, I got in touch with my DH and he recommended I call our contractor that did soooo much work for us.

I called him, he will be here within the hour and said it should be a 15 or 20 amp breaker too. I looked again and it is most definitely a 10.

It's stayed on for the last hour maybe, so I don't know what it is. After reading responses, I will NOT try to change it myself....eeeeek

Thanks for the advise all, I will let you know what happens.

= ] 

RedMulch --- 13 years ago -

ohhh.......good luck! I'm sure froggies don't like cold lily pads......bbbrrr 

Froggie --- 13 years ago -

no we don't!!!! It's warm in here again because the breaker hasn't tripped for a while. 

Froggie --- 13 years ago -

UPDATE...

Our contractor just left, the problem he thinks after crawling in the attic and going over the units outside, is the breaker wasn't in it's "slot" all the way and was making it trip. He showed me where it was lopsided in the slot. I was wrong about the amps. it's a 30 amp...see how much I know?

anyway, he tested the lines and put it back in all the way and it seems to be ok now. If it trips again he will pick another breaker and install it for me.

I tried to pay him for his time, but he wouldn't accept anything. We are a very good customer, maybe that helped.
Froggie's lilly pad is nice and toasty again.

= ] 